ReadCell
ReadCell VS80 embedded 2D scan module
Build 2D reading into machines and terminals with little room inside. The VS80 measures 40.5 × 21.5 × 25.8 mm, weighs 20 g and sends data over USB or RS232.

2D reading inside your machine
The VS80 is a module, not a stand-alone reader: it goes inside the equipment you build and sends the data over USB or RS232. It reads at any roll angle, with pitch and yaw up to ±65°.
- Very small, highly integrated body for embedding into equipment
- 5 V supply as standard, 5–24 V wide-range version on request
- USB or RS232 interface
- 1280 × 1024 resolution, white LED illumination, red laser aimer
- Roll 360°, pitch ±65°, yaw ±65°; motion tolerance 1 m/s
- Reads the full symbology list of the range, including Data Matrix, QR Code, Aztec and Han Xin
- IP52, set up with the IDManager software
Used in
Specifications
From the ReadCell VS80 datasheet, revision V01.

| Resolution | 1280 × 1024 |
|---|---|
| Field of view | 44° (H) × 33° (V) |
| Illumination | White LED |
| Aimer | Red laser |
| Scan angles | Roll 360° · pitch ±65° · yaw ±65° |
| Min. print contrast | 20% |
| Motion tolerance | 1 m/s |
| 1D | Codabar, Code 39, Interleaved 2 of 5, NEC 2 of 5, Code 93, Straight 2 of 5 Industrial, Straight 2 of 5 IATA, Matrix 2 of 5, Code 11, Code 128, GS1-128, UPC-A, UPC-E0, UPC-E1, EAN/JAN-13, EAN/JAN-8, MSI, GS1 DataBar Omnidirectional, GS1 DataBar Limited, GS1 DataBar Expanded, China Post (Hong Kong 2 of 5), Korea Post, Code 32 Pharmaceutical (PARAF) |
|---|---|
| 2D and stacked | QR Code, Data Matrix, PDF417, MicroPDF417, Aztec, MaxiCode, Han Xin, GS1 Composite, Codablock A, Codablock F |
| Code 39, 5 mil | 7–23 cm |
|---|---|
| Code 39, 13 mil | 7–40 cm |
| QR Code, 15 mil | 7–30 cm |
| Code 128, 20 mil | 6–40 cm |
| Interface | USB or RS232 |
|---|---|
| Power supply | 5 V standard · 5–24 V optional |
| Current | 300 mA operating · 70 mA standby · 240 mA at start-up |
| Dimensions | 40.5 × 21.5 × 25.8 mm |
| Weight | 20 g |
| Operating temperature | −10 to 50 °C |
| Storage temperature | −20 to 60 °C |
| Humidity | 5% to 95% RH, non-condensing |
| Ambient light | 0 to 100,000 lux |
| Shock | 2000 G, 0.7 ms, half sine, 3 axes |
| Protection | IP52 |
| Configuration software | IDManager |
Files
The datasheet downloads directly. The other files we send by email on request.
VS80 questions
Module or housed reader: which do I need?
The VS80 is for building into your own equipment. If the reader is mounted over a line on its own, take a housed reader: the ReadCell VS90 has the same 1280 × 1024 resolution, USB and RS232C, an IP54 aluminum housing and digital I/O.
How does it connect to my controller?
Over USB or RS232. Tell us what your board or controller expects and we will check it before you order.
How is it powered?
Anything from 5 to 24 V: 300 mA when operating, 70 mA in standby and 240 mA at start-up.
Can it carry our brand?
Yes. See OEM and private label for the options; MOQ is quoted per project.
Also consider
Quote a ReadCell VS80.
Tell us the quantity, the interface and what it goes into.